CO2 Power Supply

New products

LASERPWR HY-TA150 130-170W CO2 Laser Power Supply

New product

6 Months Warranty 

More details

Rs 79,000.00

Estimated Delivery: 1 to 3 days

Add to wishlist

More info

Description

Model: HY-TA150 for 130W, 150W Co2 Laser tubes 
Alias: Co2 Laser Generator, Co2 Laser Source,Co2 Laser Device, High Voltage Power Supply

Application

HY-TA150 Laser power supply is used for 130W, 150W Cutting and Engraving Acrylic, Fabric, Double Color Sheet and Rubber, etc.

Main Features

1) Good compatibility: It can be applicable to 130W, 150W Laser tubes manufactured by different factories.
2) High Voltage Power Supply: Input AC 220V or AC 110V Voltage, Max output DC 50KV.
3) This Power Supply has the ”TEST” button which can test output laser manually.
4) Easy control of laser power: Both 0-5V analog signal and PWM signal can control the laser power.
5) The power supply has the function of open circuit protection: Under the condition of good protective earthing, the power supply can work in open-circuit condition for a short time, which could avoid the damage of Laser power supply because of the bursting of Laser tube, thereby enhancing the life of power supply.
6) The power supply can take feedback interface which can be used in closed-loop control and testing the working current of laser.
7) The power supply adds a new function, that is timely scene judging which part is damaged, Laser tube or laser power.

Specification

Input

Input Voltage

AC220V or AC110V(to be specified when placing order)

AC frequency

47—440HZ

Cold Surge Current

≤60A(AC220V Input)

≤30A(AC110 Input)

Current Leakage

≤0.7mA(AC220V Input)

≤0.4mA(AC110V Input)

Output

Max Output Voltage

DC 50KV

Max Output Current

DC 38mA

Efficiency

≥90﹪(full load)

Mean Time Between Failure (MTBF)

≥10000H

Response Speed

≤1ms(from the switch Signal is given to the output current up to 90% of the setting current)

Control Interface

TTL level switch control; high or low effective level can be chosen (details refer to the control terminal specification) 

Pressure-proof

Input-Output, Input-Shell: AC1500V 10MA 60S; Output negative is connected with machine shell.

Protection

can work in open-circuit condition for a short time (Require a good protective earthing and avoid arc between the positive and the machine shell)

Environmental

Operating Temperature:-10~40℃,Relative Humidity (RH):≤90﹪

Cooling Way

Force-Air Cooling (FAC)

Dimension

L×W×H=325*240*95(mm)

Note: This machine supports LASERPWR Digital Current Meter

10 other products in the same category: